A specialized enclosure for the customer to build a workstation. Interior space for user equipment, UPS400 and the BA 27400-25.2-001 battery pack for autonomous operation.
Enclosure protection in transit per GOST 14254-2015
Maximum total load when UPS and battery are installed
Design service life of the monolithic unit
Exterior, compartments and control panel
The housing has input and output mains connectors. Installing a UPS and battery together enables autonomous operation.
Input connector (plug) with switch: ~230 V, 50 Hz — customer equipment and UPS when present
Output connector (socket) “~230 V” — external devices
DC 20.9–29.4 V for installed equipment
“24 V” connectors for external loads
USB Type-A for charging mobile devices
A monolithic container with two end covers.
Covers lock with eight tension latches each (three top and bottom, one per side) and two folding carry handles.
One cover opens a two-section bay: UPS and battery on the left, customer equipment on the right. The opposite cover is storage for portable gear.
High-strength polyethylene shell with stiffening ribs. Use standalone or as part of customer equipment.
Illuminated switches above each connector (pos. 1)
24 V automotive socket (pos. 2)
Remote UPS status indicators (pos. 3)
Battery start button for autonomous mode (pos. 4)
“~230 V Output” pass-through socket (pos. 5)
“~230 V Input” with key switch (pos. 6)
Wago 236-401 with polarity (pos. 7)
USB Type-A for mobile charging (pos. 8)
| Parameter | Value |
|---|---|
| ~230 V input connector | AC-16FL plug |
| ~230 V output connector | MAGNUM 2P+PE socket |
| Max current ~230 V in / out | 16 A* |
| 24 V connectors | Wago 236-401-8; automotive 24 V socket |
| Max current Wago 236-401-8 | 24 A** |
| Max current 24 V socket | 16 A** |
| Max current USB Type-A | 2.1 A** |
| Indicator current (4 channels) | 12.5 mA at (12.0±0.5) V |
| IP rating | IP 65 |
| Dimensions (L × W × H) | 1019 × 606 × 347 mm |
| Mass | 50 kg max |
* “~230 V input” and “~230 V output” are galvanically linked. Combined current must not exceed the input rating.
** With UPS and battery installed, total UPS load must not exceed 400 W.
Our engineers will match UPS, battery and power layout to your equipment.